Типы выключателей, доступных в стационарной версии
VM1 стационарный выключатель без основания и основных полюсов
Ur | Isc | Номинальный нормальный ток (40°C) | Тип выключателя | ||||||||
кВ | kA | H = 461 | H = 599 | H = 616 | H = 631 | H = 642 | H = 661 | ||||
D = 424 | D = 424 | D = 424 | D = 424 | D = 424 | D = 424 | ||||||
u/l = 205 | u/l = 310 | u/l = 310 | u/l = 310 | u/l = 310 | u/l = 310 | ||||||
l/g = 217.5 | l/g = 237.5 | l/g = 237.5 | l/g = 282.5 | l/g = 282.5 | l/g = 282.5 | ||||||
I = 150 | I = 210 | I = 210 | I = 275 | I = 275 | I = 210 | I = 275 | I = 275 | I = 275 | |||
W = 450 | W = 570 | W = 570 | W = 700 | W = 700 | W = 570 | W = 700 | W = 700 | W = 700 | |||
12 | 16 | 630 | VM1 12.06.16 p150 | ||||||||
20 | 630 | VM1 12.06.20 p150 | |||||||||
25 | 630 | VM1 12.06.25 p150 | |||||||||
31.5 | 630 | VM1 12.06.32 p150 | |||||||||
16 | 1250 | VM1 12.12.16 p150 | |||||||||
20 | 1250 | VM1 12.12.20 p150 | |||||||||
25 | 1250 | VM1 12.12.25 p150 | |||||||||
31.5 | 1250 | VM1 12.12.32 p150 | |||||||||
16 | 630 | VM1 12.06.16 p210 | |||||||||
20 | 630 | VM1 12.06.20 p210 | |||||||||
25 | 630 | VM1 12.06.25 p210 | |||||||||
31.5 | 630 | VM1 12.06.32 p210 | |||||||||
16 | 1250 | VM1 12.12.16 p210 | |||||||||
20 | 1250 | VM1 12.12.20 p210 | |||||||||
25 | 1250 | VM1 12.12.25 p210 | |||||||||
31.5 | 1250 | VM1 12.12.32 p210 | |||||||||
20 | 1600 | VM1 12.16.20 p210 | |||||||||
25 | 1600 | VM1 12.16.25 p210 | |||||||||
31.5 | 1600 | VM1 12.16.32 p210 | |||||||||
20 | 2000 | VM1 12.20.20 p210 | |||||||||
25 | 2000 | VM1 12.20.25 p210 | |||||||||
31.5 | 2000 | VM1 12.20.32 p210 | |||||||||
20 | 1600 | VM1 12.16.20 p275 | |||||||||
25 | 1600 | VM1 12.16.25 p275 | |||||||||
31.5 | 1600 | VM1 12.16.32 p275 | |||||||||
20 | 2000 | VM1 12.20.20 p275 | |||||||||
25 | 2000 | VM1 12.20.25 p275 | |||||||||
31.5 | 2000 | VM1 12.20.32 p275 | |||||||||
20 | 2500 | VM1 12.25.20 p275 | |||||||||
25 | 2500 | VM1 12.25.25 p275 | |||||||||
31.5 | 2500 | VM1 12.25.32 p275 |
Примечания
H = Высота выключателя. W = Ширина выключателя. D = Глубина выключателя, u/l = Расстояние между основанием и главным выводом.
l/g = Расстояние между верхним и нижним контактным зажимом выключателя. I = расстояние между центрами полюсов.
VM1 стационарный выключатель без основания и основных полюсов
Ur | Isc | Номинальный нормальный ток (40°C) | Тип выключателя | ||||||||
кВ | kA | H = 461 D = 424 u/l = 205 l/g = 217.5 | H = 599 D = 424 u/l = 310 l/g = 237.5 | H = 616 D = 424 u/l = 310 l/g = 237.5 | H = 631 D = 424 u/l= 310 l/g = 282.5 | H = 642 D = 424 u/l = 310 l/g = 282.5 | H = 661 D = 424 u/l= 310 l/g = 282.5 | ||||
I = 150 W = 450 | I = 210 W = 570 | I = 210 W = 570 | I = 275 W = 700 | I = 275 W = 700 | I = 210 W = 570 | I = 275 W = 700 | I = 275 W = 700 | I = 275 W = 700 | |||
17.5 | 16 | 630 | VM1 17.06.16 p150 | ||||||||
20 | 630 | VM1 17.06.20 p150 | |||||||||
25 | 630 | VM1 17.06.25 p150 | |||||||||
31.5 | 630 | VM1 17.06.32 p150 | |||||||||
16 | 1250 | VM1 17.12.16 p150 | |||||||||
20 | 1250 | VM1 17.12.20 p150 | |||||||||
25 | 1250 | VM1 17.12.25 p150 | |||||||||
31.5 | 1250 | VM1 17.12.32 p150 | |||||||||
16 | 630 | VM1 17.06.16 p210 | |||||||||
20 | 630 | VM1 17.06.20 p210 | |||||||||
25 | 630 | VM1 17.06.25 p210 | |||||||||
31.5 | 630 | VM1 17.06.32 p210 | |||||||||
16 | 1250 | VM1 17.12.16 p210 | |||||||||
20 | 1250 | VM1 17.12.20 p210 | |||||||||
25 | 1250 | VM1 17.12.25 p210 | |||||||||
31.5 | 1250 | VM1 17.12.32 p210 | |||||||||
20 | 1600 | VM1 17.16.20 p210 | |||||||||
25 | 1600 | VM1 17.16.25 p210 | |||||||||
31.5 | 1600 | VM1 17.16.32 p210 | |||||||||
20 | 2000 | VM1 17.20.20 p210 | |||||||||
25 | 2000 | VM1 17.20.25 p210 | |||||||||
31.5 | 2000 | VM1 17.20.32 p210 | |||||||||
20 | 1600 | VM1 17.16.20 p275 | |||||||||
25 | 1600 | VM1 17.16.25 p275 | |||||||||
31.5 | 1600 | VM1 17.16.32 p275 | |||||||||
20 | 2000 | VM1 17.20.20 p275 | |||||||||
25 | 2000 | VM1 17.20.25 p275 | |||||||||
31.5 | 2000 | VM1 17.20.32 p275 | |||||||||
20 | 2500 | VM1 17.25.20 p275 | |||||||||
25 | 2500 | VM1 17.25.25 p275 | |||||||||
31.5 | 2500 | VM1 17.25.32 p275 | |||||||||
24 | 16 | 630 | VM1 24.06.16 p210 | ||||||||
20 | 630 | VM1 24.06.20 p210 | |||||||||
25 | 630 | VM1 24.06.25 p210 | |||||||||
16 | 1250 | VM1 24.12.16 p210 | |||||||||
20 | 1250 | VM1 24.12.20 p210 | |||||||||
25 | 1250 | VM1 24.12.25 p210 | |||||||||
16 | 630 | VM1 24.06.16 p275 | |||||||||
20 | 630 | VM1 24.06.20 p275 | |||||||||
25 | 630 | VM1 24.06.25 p275 | |||||||||
16 | 1250 | VM1 24.12.16 p275 | |||||||||
20 | 1250 | VM1 24.12.20 p275 | |||||||||
25 | 1250 | VM1 24.12.25 p275 | |||||||||
16 | 1600 | VM1 24.16.16 p275 | |||||||||
20 | 1600 | VM1 24.16.20 p275 | |||||||||
25 | 1600 | VM1 24.16.25 p275 | |||||||||
16 | 2000 | VM1 24.20.16 p275 | |||||||||
20 | 2000 | VM1 24.20.20 p275 | |||||||||
25 | 2000 | VM1 24.20.25 p275 | |||||||||
25 | 2500 | VM1 24.25.25 p275 |
Примечания
H = Высота выключателя. W = Ширина выключателя. D = Глубина выключателя, u/l = Расстояние между основанием и главным выводом.
l/g = Расстояние между верхним и нижним контактным зажимом выключателя. I = расстояние между центрами полюсов.
"